1. How to connect the anti-collision signal of the welding torch?
The collision avoidance feature requires the use of an EE interface, in which one termination is *XHNBK signal, the other is terminated at 24V, and then the claw break function is enabled in the system-configuration configuration.
2. The robot can't move manually?
To ensure that there are no faults, check whether the teach pendant switch is set to on, whether the mode switch is firmly dialed to T1 or T2, then check whether the UI signal meets the operating conditions, and if necessary, turn off the external dedicated signal in the system - configuration.
3. How to modify the robot's range of motion?
It can be modified in the system-axis action range, but for M-10iA and 20iA robots, attention should be paid to the installation of the external pipeline of the J6 axis, and it should be modified in the control start mode.
4. How to reach 100% speed directly when running the program automatically
Insert the Override command before the motion command in the program and set it to 100.
5. Pause and then start?
The robot has no alarm, UI signals 1, 2, 3, 8 are ON, UO signal 1 is ON, and the 6th startable program of sending pulse UI signal continues to run.
6. The robot output is not 24V when it is ON?
Check whether the 24V of the common side of the DOSRC output signal on the IO signal board is normal.
7. The USB flash drive is not recognized when it is inserted on the TP, but the files can be backed up on the control cabinet?
Some TP cables in the R-30iA control cabinet do not support USB flash drives, and need to be replaced with TP cables that support USB flash drives (A660-2006-T840).
8. Does the Mate cabinet motherboard support the vision function?
The last digit of the 12-bit alphanumeric combination of the Mate cabinet motherboard model 0 does not support vision, and the motherboards with 1 and 2 support vision.
9. TP button to start the program?
After setting the program to a macro, it can be started by pressing a button on the TP (macro startup is set to UK mode).
10. What is the maximum number of registers that can be expanded?
When the register expansion function is installed, the maximum number of numerical registers is expanded to 5000, and the maximum number of position registers is extended to 2000.
11. How many levels of bot password functionality are there?
Installation: You can assign a username, password, and password level. Usernames and passwords can be erased. You can set the password log to be valid or invalid. You can set the number of password users in the system. It is possible to perform all operations of settings, programs, and operators. (Only 1 user can be installed) Setter: You can perform the normal operation in the setting system. Programmer: Can perform operations at a higher level than the operator user. Operator: Can perform basic operations.
12. How to enable the robot's original path recovery function?
The following system variables are used to switch between valid and invalid original path restoration:
$SCR.$ORG_PTH_RSM
TRUE: The original path is restored to work
FALSE: The original path reinstatement is invalid
13. What is the use of a robot's diagnostic backup?
Diagnostic backup is a function that allows you to perform a simple operation after an exception has just occurred, and save the internal data at that moment in FROM. Some internal data is lost when the power is cut off. After using this function to save the internal data in FROM, we will be able to conduct an investigation by sending the image backup to Fanuc.
14. How to enable additional axis collision detection?
Change the following system variables
$SBR[n].$PARAM[112] = 2097152 / ($SBR[n].$PARAM[47])
$SBR[n].$PARAM[119] = 7282
$SBR[n].$PARAM[120] = -7282
n: The number of the shaft in terms of the hardware aspect of the additional shaft.
If it is an additional axis of the robot, it is usually set to a value of 7 or later.
15. How to exit the HMI interface?
Select FCTN Menu - Next - Disable HMI Menu
16. How to output the alarm status of the robot to the peripheral devices?
Assign and use UO6 error signals
17. The robot main menu - File menu - "Switch Storage Device" does not have that option?
Press MENU-SETUP-GENERAL to switch the system language to English
18. What are the installation conditions for the robot?
Ambient temperature: 0~45°, ambient humidity: usually below 75%RH (no condensation), short-term (within one month) below 95%RH; Allowable altitude: below 1000m above sea level; Vibration acceleration: 4.9m/s² (0.5G) or less; There should be no corrosive gases.
19. What is the repeated positioning accuracy of the robot?
For details, please refer to the "Basic Specifications" section of the operation manual of the mechanism part of the corresponding model.
20. What are the common coordinate systems for robots?
Joint Coordinate System, Cartesian Coordinate System, World Coordinate System, Tool Coordinate System, User Coordinate System
21. What is the grease replacement interval for the drive mechanism?
It must be installed every 3 years or replaced in a shorter period of 11,520 hours of operation.
22. What is the battery replacement cycle of the drive mechanism?
It must be replaced regularly every year; It needs to be replaced when the robot is powered on.
23. Backup battery replacement cycle for memory?
Batteries must be replaced with new ones every 4 years
24. How to confirm the model number of the memory spare parts and how to confirm their universality
You need to check the twelve-digit code at the beginning of the sign A05B and A06B of the spare parts; Parts with consistent 12-digit codes can be used with each other.
25. What are the precautions for replacing control cabinet spare parts?
The versatility of the spare parts must be confirmed; Do a good job of backing up the image of the device and all common files, and if you replace the core components of the storage, you must import them back to the image backup.
26. Can the robot control cabinet and the body be used interchangeably?
The pre-installed software configuration of the device is inconsistent with the zero data of the device, so it is not recommended to replace it.
27. What are the robot password levels?
Installation, Programmer, Programmer, Operator, User Customization
28. When is a zero calibration required?
(1) The backup battery of the control cabinet is exhausted, or the zero position data caused by the initialization start is erased, etc., resulting in the loss of the zero point calibration data of the robot.
(2) Zero point data loss due to the exhaustion of the backup battery after the pulse encoder of the mechanism department, the replacement of encoder, motor, encoder cable, etc.
(3) Collision with the mechanism part and cause the pulse encoder and shaft angle to deviate, or replace the transmission part of the mechanism part.
29. What are the types of zero point calibration?
Full axis zero position calibration, simple zero point calibration, simple zero point calibration (single axis), single axis zero point calibration, visual zero point calibration (optional), input zero point calibration data.
30. What are the types of I/O?
Peripheral I/O, operator panel I/0, digital I/0, group I/O, analog I/O, safety I/O
31. What are the types of UOP assignments?
Full distribution (can be assigned to peripheral I/O using all peripheral I/O 18 input points and 20 output points of physical signal;
Abbreviated allocation (the number of usable points is small, and the physical signal of 8 input points and 4 points of output of device I/O is allocated to peripheral I/O).
32. Is the Chinese language mandatory to install option?
The Chinese language is shown as an option
33. What is the robot's handling posture?
For details, please refer to the "Handling and Installation" section of the operation manual of the mechanism department of the corresponding model.
34. What are the types of register instructions?
Numeric Register Instructions, Position Register Instructions, Position Register Element Instructions, Stacking Register Instructions, String Register Instructions
35. What is the default number of numeric registers?
As standard, 200 numerical registers (via PREV NEXT to restart the control cabinet and enter the control start [CTRL START] mode) to complete the setting change.
36. Is it not possible to increase the OVERRIDE speed for the maximum magnification in manual mode?
When the control is started, confirm the value of the system parameter $SCR.$JOGOVLIM.
37. Is it not possible to increase the maximum override speed of the program's operation?
When the control is started, confirm the value of the system parameter $SCR.$RUNOVLIM.
38. What is the way to start the robot's controls?
Initialization start, control start, cold start, hot start
39. How to view the robot software version screen?
Press "MENU" - "0" (next page) - "4" (status) - "F1" (type) - software or version ID
40. What are the types of robot backup files?
Program files (*. TP), the default logical file (*. DF), system files (*SV), I/O profiles (*. I/O), data files (*. VR)
41. What is the number of interference areas of the robot?
7DC2/01 or later, the maximum definable interference area is changed from 3 to 10.
42. How to enter the robot setting reference position screen
Press "MENU" - "6" (Settings) - "F1" (Type) - Reference position
43. How many reference positions can be set?
The reference position is a fixed position that is frequently used in the program or joging, and can be set to 10 reference positions (up to 64 after changing the system parameters).
44. How to see if the external dedicated signal (UOP) is on/off?
Press "MENU" - "0" (next page) - "6" (system) - "F1" (type) - configuration - item 7 (external dedicated signal UOP)
45. What are the general things to set up?
Pause Alarm Function, Language Selection, Position Compensation Command Ignore Function, Tool Compensation Ignore Function, Enable Visual Compensation Command.
46. Whether the pause alarm function and the interference area function can be used at the same time?
The pause alarm function and the interference area function cannot be used at the same time.
47. What are the effects of load setting?
Improved performance (reduced vibration, improved cycle time) and more effective performance of dynamics-related functions (collision detection function, gravity compensation function).
48. How many groups can be set for load setting information?
10 types of load information can be set for load setting information.
49. How to check if the end effector is broken (Hand Broken) on/off?
Press "MENU" - "0" (next page) - "6" (system) - "F1" (type) - configuration – End Effector Breakage (Hand Broken)
50. How to set up remote/local boot?
Press "MENU" - "0" (next page) - "6" (system) - "F1" (type) - configure - select "remote/local"
51. Is it possible to set the common voltage of the RI signal of the end effector (EE interface)?
The amplifier COM1 can be set to be +24V common on the A side and 0V common on the B side at the cross-wire pin switch of the amplifier.
52. Is it possible to set the output voltage of the RO signal of the end effector (EE interface)?
The output voltage of the RO signal of the end effector (EE interface) is +24V and cannot be changed.
53. How to reset the normal robot alarm SRVO-230/231?
Press "MENU" - "4" (alarm history) - "F4" (RES_1CH) - F4 - to reset
54. The machine can be turned on normally, except that the teach pendant is not lit, the others are normal, what aspects should be checked?
Carefully check whether the cable of the teach pendant is bent and broken, short circuit to the ground and other abnormalities, and at the same time check whether the fuse of the emergency stop plate corresponding to the teach pendant is blown or not.
55. The robot can't be turned on normally, what aspects should be checked?
Confirm whether the input voltage is normal, confirm whether the teach pendant interface is loose, whether the boot signal EXON/EXOFF signal is on, whether the teach cable is in good condition, whether the motherboard connector has an alarm code, whether the motherboard connector is loose or has an incorrect connection, and whether the emergency stop plate is fused.
56. How to check the bot alarm code?
Press "MENU" - "4" (Alarm) - "1" (Alarm Log) to view
57. How to view the current axis position of the robot?
Press the "POSN" button directly on the teach pendant
58. What should you do if you can't find the zero calibration screen?
Check whether the value of the system parameter $MASTER_ENB is 1.
59. How to recover from the mismatch of the pulse position of the robot?
On the zero point calibration page, press F3 (RES-PCA) and then F4 (YES) to change the system parameter $DMR-GRP to True for $Master-Done, and then shut down and restart the controller.
60. How many programs can be set up for a Robot Initiation Request (RSR)?
The Robot Initiation Request (RSR) can be set up to 8 programs.
61. What is the naming convention for Robot Initiation Requests (RSRs)?
The program name is 7 digits, which consists of RSR and 4 bits of program number (insufficient bits are filled with 0).
62. How many programs can be set up for the Robot Number Selection (PNS)?
The Robot Program Number Selection (PNS) can be set up to 255 programs.
63. What is the naming convention for the Robot Number Selection (PNS)?
The program name is 7 digits, which consists of a PNS and a 4-digit program number (insufficient bits are filled with 0).
64. What are the types of actions of robots?
Joint action, straight line action, A arc action, C arc action
65. What are the methods of starting a robot?
Teach pendant, operator panel start button, peripheral signals
66. What are the two action elements of a robot?
Velocity multiplier (the speed of the robot's movement), spatial coordinate position data (the robot's motion space)
67. Instructions in the bot calling the program?
Press "SELECT" to enter the program list, select a program "enter" to enter, press the "NEXT" key in the upper right corner of the teach pendant, press the INST corresponding to the "F1" key, and finally select the appropriate program instruction in instruction.
68. How to switch between Chinese and English languages?
Press the "MENU" button in the teach pendant, select up and down to enter "SETUP", select "GENERAL" to the right, and switch "CHINESE/ENGLISH" in "LANGUAGE".
69. Can the R-30iB Mate plus robot control cabinet remove the speed magnification limit when the DEADMAN switch is released in T1 mode?
No, the R-30iB Mate plus robot control cabinet is not allowed to modify the speed magnification parameters in this case due to safety considerations.
70. How to cut multiple screens in the teach pendant?
Press and hold the "SHIFT" key and the "DISP" key at the same time, and select the number of screens you want to switch out, "SINGLE", "DOUBLE", "TRIBLE"; Click the "DISP" button to switch between screens.
71. How to see the current/disturbance value of each axis of the robot?
Press the "MENU" button to go to the next page, press the "STATUS" button, press the "AXIS" button, press the "NEXT" button, and press the "DISTURBANCE" button to view the current/disturbance values of each axis.
72. Jog robot position data changes but in fact the machine is not moving?
Press MENU-TEST CYCLE-SETUP-GROUP MOTION to display as disabled and modified to enable mode.
73. The robot speed ratio cannot be adjusted?
In the system configuration menu, the button to enable automatic mode speed adjustment is active.
74. External Signal Termination Procedure?
Enable items 9 and 10 in the system configuration menu, and change the UI [4] signal status during program operation to terminate the currently running program.
75. How to set the mounting angle of the robot?
(1) Power off the controller, press the "PREV" and "NEXT" buttons at the same time, turn on the power, and then select "3.Controlledstart"
(2) Press the MENU key and select "9 MAINTENANCE"
(3) Select the robot with the angle set and press F4 MANUAL
(4) Find MOUNT ANGLE SETTING option to set the mounting angle of the robot
(5) Press the ENTER key until you return to the robot model screen. Press the FCTN button and select "1.START(COLD)"
76. The zero calibration screen disappears, and how to display it again?
In System-Variable, change the variable $Master_enb to 1: MENU-SYSTEM-VARIABLE
77. What are the types of input and output signals in CRMA15 and 16?
The input signal can be adjusted high and low via SDICOM pins. When SDICOM is connected to 24V: active low, when SDICOM is connected to 0V: the active high output signal is only active high.
78. How to configure the brake number of the additional shaft?
The brake number of the additional shaft motor is 1 when plugged into the six-axis amplifier of the body, 2 when plugged into the CRR65C, and 3 when plugged into the CRR65D.
79. How to make an IO input signal always ON?
In the I/O allocation settings, set the rack number of the corresponding input signal to 35, the slot to 1, and the start point to 1.
80. How does CRMA15/16 restore the default allocation?
First, clear all settings in DODI and UOUI signal configuration, then find "UOP Assignment" in the system configuration, the default is FULL, select "CRMA16 Easy Assignment" after entering, and then restart.
81. PR register expansion?
In the control startup mode, press MENU-next page "1" program setting, and modify the number of PR registers in item 3, the default is 256.
82. DIDO signal expansion?
Change the value of $MAX_DIG_NUM in the system variable, the default value is 512.
83. The computer displays a teaching pendant prompt that there is no authority and a password is required?
Go to the 5th item HTTP in Settings - Host Communication, move the cursor to the leftmost column, and unlock the functions you need.
84. How to eliminate the robot pause light?
It is required to enable the UI2 signal.
85. Can the robot teach pendant be used with other robots?
Inform the control cabinet that it can also be used universally (R-30IB or R-30IB MATE)
86. Is it possible to swap the motherboard for testing, as the robot is unable to access the system?
It is recommended to replace a full set of motherboards to test whether the failure is transferred.
87. Is there an end command required for changing the operating speed after using the OVERRIDE instruction?
Tell that there is no end command, and if you change the speed, you can use the OVERRIDE command again.
88. How is the arm break signal output to the periphery?
It is recommended to use the UO6 signal to output the alarm or add the alarm output software.
89. What are the requirements for external axes for robot dual drives?
The motor rotation direction is set in the same way as the independent external axis or positioner within the group.
90. Is there any special requirement for adding KA analog input and output signal board to A cabinet ?
An additional small electric control box is required.
91. How to determine the zero position of the M-20iA robot with 5 and 6 axis zero position scale mark wear?
The No. 5 axis is parallel to the ground at zero position, and the dowel pin on the flange of No. 6 is in the zero position at 12 o'clock
92. Group 2 Zero Position Proofreading Logo?
"G2 Joint" is displayed on the Zero Position Proofreading menu page.
93. USB flash drive can back up files but fails to load files?
The 32G capacity U disk used by the customer, it is recommended to use the U disk with a capacity of less than 8G (sandisk brand compatibility is better)
94. How to make an IO input signal always ON?
In the I/O allocation settings, set the rack number of the corresponding input signal to 35, the slot to 1, and the start point to 1.
95. How to invoke the arc command?
After creating a new point statement, move the cursor to J or L and press F4 to select the arc command.
96. How to increase the upper limit of the PR register?
(1) Press the "PREV" and "NEXT" buttons to turn on the power supply, and then select "3.Controlledstart"
(2) Press the MENU key, then select "0 NEXT", select "PROG SETUP"
(3) Find the POSITION REG option and modify the corresponding number to modify the upper limit of the PR register.
(4) Press the FCTN button and select "1.START(COLD)" to return to normal mode
97. How to wire DOSRC in CRMA15 and 16?
In CRMA15, 16, DOSRC needs to be connected to an external power supply of 24V.
98. Which network ports in the control cabinet can be used for Ethernet communication?
CD38A and CD38B are used for Ethernet communication, where CD38A corresponds to port 1 and CD38B corresponds to port 2.
99. How to view the TP program on computer?
Select ASCII program for backup at the time of backup
100. How to know in advance that the battery is low?
The UO[9] signal can be used to output ON when the battery is low.
101. How the CRMA15/16 implements low-level inputs
The common terminal of the input SDICOM1~3 is connected to 24V, and the input signal is ON when it is connected to 0V
102. How to import the .LS file programmed by ASCII into the robot
The "ASCII Form Program Loading Function" (R796) must be added to the system. LS files can be loaded directly in the file menu by pressing F3.
103. If the zero point is lost, can the factory's MASTER COUNT value be directly input to restore the zero position?
The premise of directly entering the factory MASTER COUNT value to restore the zero position is that the robot has not lost the zero position due to these methods: the main battery is de-energized, the encoder and cable connectors, motors and reducers are disassembled.
104. The zero calibration option could not be found
Changed the $MASTER_ENB in the system-variable from 0 to 1
105. The pause indicator of the robot cannot be eliminated
The UI2 signal is sent to the robot through an external device, which must be a constant ON signal, which can be eliminated by pressing RESET.
106. There is no editing option on the program's editing screen
After pressing the FCTN button, press the page to find the full menu/easy menu switching option, and switch to full menu.
107. How to use the OFFSET directives OFFSET and PR
Add the OFFSET command at the end of the motion statement, press the F1 command to find the OFFSET at the end of the cursor movement, select the PR value later, and then set the relative PR value on the PR editing screen.
108. How to wire the CRM15,16 input signal
Confirm whether 24V is valid or 0V is valid, such as 24V is active, 0V and the common terminal are shorted, UI, DI signals are connected to the outside and returned to 24V on the terminal block, and the opposite is true when 0V is active.
109. How to wire the CRM15,16 output signal
DOSRC1,2 on the terminal block is connected to an external 24V, DO, UO signals are connected to an external relay, and 0V on the board can be returned.
110. DIDO signal interconnection capacity expansion
Enter the control boot mode, press MENU, and select the program in the first item on the next page, which contains the DIDO interconnection expansion option.
111. How to switch between PNS and RSR
In the MENU, the first item in the selector in the settings can be togglerated, but note that to switch to RSR mode, the assignment of UI [17] must not coincide with other UI signals.
112. The zero point calibration interface could not be found
In MENU, in the second variable in the system, find $MASTER_ENB and change it from 0 to 1.
113. How to modify into Chinese
In the second item of MENU, SETUP, GENERAL, select CHINESE
114. Speed cannot be increased to 100% in manual mode.
In control boot mode, press MENU, select the variable, and modify the $SCR.$SFJOGOVLIM to 100.
115. How to make the signal emulation output
Select the DI signal in the IO interface, move the cursor to the SIM, and change it to S to simulate the output signal.
116. The robot moves to the reference position, but there is no signal output
In the setting interface, enter the reference point setting, check that the signal definition has been set, and check whether the allowable error range after the J1 to J6 axis values is set, generally set to about 1 degree
117. How the program is aborted
Manual interruption of the program can be achieved by pressing the FCTN button and selecting the program termination option, while automatic interruption can be performed using the UI4 signal.
118. How to replace the battery of the robot body
Open the lid of the battery compartment in the power-on state, take out the battery, put in the new battery according to the diagram, pay attention to the positive and negative poles, and then close the battery compartment lid.
119. What is the position of the M10, 20I series robot oil drain
J1, J2, J6 axis in any position, J4 axis replacement, J4 axis -180, J5, J6 replacement, J3 -30, J4 -70, J5 0 degrees.
120. How to change the jog direction of the welding torch
Go to the control splash screen, select the main menu, maintenance options, cursor selection, and define the opening and closing direction of the welding torch in the manual settings of the servo welding torch.
121. The special signal for external equipment failure cannot be input, how to use it in an emergency
You can enter the dedicated signal configuration screen and set it to the normally open state (rack 35, slot 1, start point 1).
122. How to configure the robot mounting screws
Look for the installation instructions in the installation section of the robot operating manual.
123. The bot editor is unable to insert a blank line
Check and turn on the enable switch located at the upper left corner of the teach pendant.
124. The robot coordinate system is preceded by a W/ flag
Select the FCTN menu to turn off the toggle wrist jog function
125. J4, J5, J6 shafts zero scale wear
The side characters of the arm are perpendicular to the ground at zero degree on the J4 axis, parallel to the ground at zero degree on the J5 axis, and the positioning pin on the flange is at the 12 o'clock position of the clock at zero degree on the J6 axis.
126. There is a leakage phenomenon in the robot body
Check whether the robot grounding wire is connected to the N line of other equipment, and whether the robot external pipeline is worn.
127. UO[1] signal output premise
The robot has no alarm and meets the conditions for remote control.
128. The robot does not weld and does not alarm in automatic mode
In the interface signal of the robot cell, the input signal of DRY RUN is ON, and the input signal is cut off and welded normally.
129. Trace card fiber connections
Fiber optic communication cable from axis card to 6-axis amplifier to tracking card, or axis card to tracking card to 6-axis amplifier (tracking card has 2 optical interfaces).
130. What is the name of the visual interface on the motherboard?
The corresponding interface name of the R-30IA system control cabinet is JRL6, and the corresponding interface name of the R-30IB system control cabinet pair is JRL7.
131. When can the pulse value data be used
Used in cases where the zero calibration data is lost while the pulse value data is still valid.
132. How the robot control cabinet is connected to an external E-STOP?
Connect the contacts of the emergency stop switch to the EES1 and EES11, EES2 and EES21 terminals.
When the contact is opened, the robot stops according to the pre-set stop mode.
When using the contacts of relays and contactors without using switches, spark arrestors are installed on the coils of the relays and contactors to reduce noise.
When these signals are not in use, install jumper cables.
133. How the robot control cabinet is connected to an external safety gate or light barrier?
Connect the contacts of the external safety gate or light barrier to the EAS1 and EAS11, EAS2 and EAS21 terminals.
When the contact is turned on in AUTO mode, the robot will stop according to the pre-set stop mode.
In T1 or T2 mode, the robot can be operated even when the door of the safety barrier is already open by keeping the safety switch correct.
When using the contacts of relays and contactors without using switches, spark arrestors are installed on the coils of the relays and contactors to reduce noise.
When these signals are not in use, install jumper cables.
134. What are the conditions for the output signal UO[1] (CMDENBL) to become ON??
The input signal UO[1] (CMDENBL) can be received and output when the following conditions are true.
• The remote control condition is established.
• The actionable condition is established.
• The continuous operation mode is selected (the single-step mode is not valid).
This signal indicates that a program containing actions (groups) can be initiated from a programmable device.
135. Additional axis travel switch connection
The additional axis travel switch signal is connected to pins 1 and 2 of the 6-axis amplifier CRM68 socket.
136. Robot factory zero position data
After the customer provides the serial number of the robot, it can inform the factory zero position data.
137. How to exit the robot control startup mode.
In control start mode, press the FCTN button and select "COLD Start" to automatically enter the general menu mode.
138. The robot motor that has just arrived does not have a protective cover
The motor cover is an option, and the motor cover will only be installed when it leaves the factory after it is selected in the purchase order of the new machine.
139. When the robot is turned on, the switch of the factory distribution box trips
Check whether the capacity of the factory switchbox switch matches the robot model: check the power supply capacity description in the installation section of the robot controller maintenance manual.
140. System - Configuration item 7: What is the function of the UOP external control signal
Active/inactive handover of dedicated external signals. If it is disabled, ignore peripheral input signals (UI[1]~UI[18])
141. What is the effect of the robot after the load is set
By setting the load information appropriately, the following effects will be achieved, and by setting the load information appropriately, the following effects will be achieved. Improved operating performance (reduced vibration, improved cycle time, etc.) enables more effective performance of dynamics-related functions. (Performance improvements such as collision detection function and gravity compensation function.)
142. What is the function of group signals in the robot IO
Group I/O (GI/GO) is a general-purpose digital signal used to aggregate multiple signal lines and exchange data. The value of a group signal is expressed as a numerical value (decimal number), which is converted or inverted into a binary number and then exchanged through the signal line.
143. What is the function of peripheral device I/O (UOP) in robot IO
Peripheral I/O (UI/UO) is a dedicated signal in a system whose purpose has been determined. These signals are connected to the programming device and peripheral devices from the processing I/O printed circuit board (or I/O unit) through the following interfaces and I/O Links, and the robot can be controlled from the outside.
144. What are the naming requirements for bot names?
The length of the program name is 1~36 characters. The program name must be unique to the program.
Characters that can be used
Characters: English letters (uppercase letters only).
Numbers: 0~9. Program names cannot start with a number.
Symbol: _ only (underscored). @ and * cannot be used.
The following program names cannot be used.
CON,PRN,AUX,NUL,
COM1,COM2,COM3,COM4,COM5,COM6,COM7,COM8,COM9,
LPT1,LPT2,LPT3,LPT4,LPT5,LPT6,LPT7,LPT8,LPT9
145. What is the rack number of the MB board of the Process IO
The rack number is 0.
146. How to clear the exclamation mark in the upper right corner of the teach pendant
Press the 'diag/help' button on the instructional device, press F2 to clear, select 1 day or 1 week, and then confirm.
147. How to add a robot zero encoder value
Modify the variable $DMR_GRP in $MASTER_COUNT, and after the modification is completed, you need to change the $MASTER_DONE of $DMR_GRP to TRUE, and restart the controller.
148. Can the teach pendant and teach pendant line of different robots be mixed?
If the control cabinet model of the robot is the same, it can be mixed.
149. How to recover a forgotten password?
Can only be initialized
150. How to install the robot upside down installation method
Inform the robot that it is fixed in the same way as the seat, but you need to place the robot in the hoisting position by yourself.
151. How to correctly connect the new control cabinet to the power supply, turn on and power on
Carefully check the supply voltage on the nameplate on the lower side of the control cabinet and connect the power supply cable.
152. The teach pendant cannot be used for program editing
Turn on the ON/OFF switch in the upper left corner of the revelation device.
153. The robot selects the RSR startup mode and changes back to PNS after restarting
Check that there is a duplicate assignment of UI signals in the MENU-I/O menu (UI17 and UI6 are mostly assigned to the same signal port).
154. The bot main menu does not have a file option
Select FCTN Menu - Easy/Full Screen Toggle Function.
155. What is the maximum number of additional axes that can be added to the robot
At present, the robot controller can control up to 40 axes and can be controlled in multiple groups.
156. The difference between CNT and FINE for robot motion commands
The type of termination point is different, CNT is excessive point control, which makes the point movement more coherent; FINE is the precise point of arrival location.
157. How to check the accuracy range of TCP work?
Switch the tool coordinate system index, and rotate the robot's fingertip around the reference point in the X, Y, and Z directions, observing the deviation distance of the fingertip from the reference point: the smaller the value, the better.
158. When can QUICK MASTER be used to restore to zero?
When the robot loses its reference point due to electrical or software malfunctions, QUICK MASTERING can be used.
159. How to check the time of the clock command
The PRG TIMR in the status bar displays the clock registers.
160. Will the robot R register be automatically cleared when the controller is restarted?
The data in the robot R register will not be automatically cleared when the controller is restarted, and it needs to be cleared manually or assigned 0 to the instruction in the program.
161. The robot maintains a constant speed during operation
The motion commands for L can maintain a constant speed in intervals other than the starting and stopping phases.
162. The location register does not modify the data, but the position changes
The data in the position register does not have the attribute of the coordinate system serial number, and the position under the sequence number of different coordinate systems will be different, and it is recommended to store the data in the form of joints, so the position will not change with the coordinate system serial number.
163. Can the number of RO signals of the robot be modified, and the parameters can be increased?
The robot RO signal cannot exceed 8, and the parameters cannot be modified to increase the number of RO signals.
164. The previous page cannot be retained after the bot is restarted
MENU-0 NEXT-6 SYSTEM-5 CONFIG enable item 1 "hot start power outage handling", and the previous page can be retained after the controller is restarted.
165. What are the types of system files and what are the contents stored separately?
A system file/application file (*.sv) is a file that is stored for the control program of the system running the utility software or for use in the system. There are several types of system files.
· SYSVARS.SV Stores the settings of system variables such as reference position, joint range of motion, brake control, etc.
· SYSFRAME.SV Stores the settings of the coordinate system.
· SYSSERVO.SV Store the settings of the servo parameters.
· SYSMAST.SV Stores zero calibration data.
· SYSMACRO.SV Stores the settings of the macro.
· FRAMEVAR.VR Stores data such as reference points and annotations used for coordinate system setting. The data of the coordinate system itself is stored in the SYSFRAME.SV
166. What are the types of data files and what are the contents stored separately?
NUMREG.VR Store the data of the numerical registers.
POSREG.VR The data of the storage location register.
STRREG.VR Store the data of the string register.
PALREG.VR Stores the data of the palletizing register (only when using the palletizing register option).
I/O Assign data files(*IO)
DIOCFGSV.IO Stores the settings for I/O allocation.
Robot configuration data file (*.DT)
Stores the settings on the robot settings screen.
The file name varies depending on the different models.
167. Description of the system timer
Power-on time: The time when the power supply to the control unit is turned on.
Servo ON time: The time when the alarm is cleared and the system is ready (servo on).
Working hours: The time when the program is executed. Except in the midst of suspension.
Wait time: The time it takes to execute the on-call order.
Brake release time: The time at which the brake was released.
168. What are the stopping methods of the robot
(1) Power-off stop (equivalent to IEC 60204-1 category 0 stop)
(2) Control stop (equivalent to IEC 60204-1 Category 1 stop)
(3) Hold (equivalent to IEC 60204-1 Category 2 stop)
169. How to set the reference position signal UO7
The reference position signal (ATPERCH) is output when the robot is in a predetermined reference position.
Up to 10 reference positions can be defined, however, this signal is output when the robot is in the 1st reference position. Other reference positions are assigned generic signals.
170. Can backups be imported between robots?
Robots of the same model, the same control cabinet and the same software system can load full backups of each other, but attention should be paid to the changes of system settings and zero positions.
171. There are no annotations for signals in the robot program
After entering the program editing interface, select the F5 editing function and turn on the annotation function.
172. The painting robot MENU-SETUP does not have a program selection interface.
Inform the painting robot that it can only be started with a JOB number.
173. The programming interface shows icon editing, no touch screen, no command can be selected, how to turn it off?
Press "NEXT" in the programming interface, press F5 "Edit", move the cursor to "Icon Editor" in the options menu, and press F4 to close the Icon Editor.